OPERATION MANUAL  
WV-2HG SERIES  
GRIDDLE AND  
HOTPLATE  
COOKTOP  
with  
UNIVERSAL HOOD  
MODELS:  
WV-2HFG  
WV-2HFGRW  
WV-2HFGRWT  
WV-2HSG  
WV-2HSGRW  
WV-2HSGRWT  
Includes  
INSTALLATION  
USE & CARE  
WV-2HGRW  
IMPORTANT: DO NOT DISCARD THIS MANUAL  
This manual is considered to be part of the appliance and is to be given to the OWNER or  
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of  
this appliance. Additional manuals are available from your WELLS DEALER.  
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR  
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any  
questions concerning installation, operation or maintenance of this equipment.  
PRINTED IN UNITED STATES OF AMERICA  
p/n 304456 Rev. D ECN-13463  
M508 080523 cps  
 
INTRODUCTION  
3ø AMPS  
L2  
1ø  
AMP  
S
ROLL  
WARMER 50/60 Hz  
VOLTS  
DIMENSIONS  
POWER CORD  
MODEL  
WATTS  
L1  
L3  
208V  
16  
18  
21  
23  
19  
21  
23  
26  
32  
35  
35  
38  
32  
35  
35  
38  
23  
24  
24  
24  
26  
27  
26  
27  
38  
41  
43  
46  
42  
45  
46  
50  
8,000  
9,900  
8,900  
11,100  
8,675  
10,800  
9,575  
12,000  
WV-2HFG  
NO  
240V  
208V  
30-3/8” WIDE  
(42-3/8" wide including spacers)  
79-1/8” HIGH  
35-3/8” DEEP  
Power Cord (when provided):  
NEMA 15-60P  
WV-2HFGRW  
WV-2HFGRWT  
YES  
240V  
208V  
WV-2HSG  
NO  
240V  
208V  
WV-2HSGRW  
WV-2HSGRWT  
YES  
240V  
Minimum clearances required from unit to nearest combustible surface or object  
BACK  
n/a  
SIDE  
6
BOTTOM  
TOP  
19  
inches  
6
millimeters  
n/a  
152  
152  
483  
1
 
Fig. 1 Ventilator Section Operating Features & Controls  
2
 
VENTILATOR SECTION  
ITEM  
DESCRIPTION  
COMMENT  
1.  
NAMEPLATE  
Gives manufacturer, make and model description. Also lists voltage  
and amperage data.  
5.  
APPLIANCE LIGHT  
ON when hood power switch is ON. Illuminates cooktop.  
a6.  
FIRE SUPPRESSION  
AGENT TANK (1.5 gal.)  
Container for Ansulex™ Low-pH liquid fire suppression liquid.  
8.  
9.  
ADJUSTABLE (FRONT) LEG  
RIGID (REAR) CASTER  
Allows the unit to be leveled.  
Allows the unit to be easily positioned by lifting the front of the unit  
slightly.  
a10.  
a11.  
MANUAL PULL STATION  
FUSIBLE LINKS  
Provides a means of manual activation of the fire suppression system.  
PULL ONLY IN CASE OF FIRE!  
Designed to break at rated temperature. Breaking (i.e. fire on the  
cooktop) activates fire suppression system. Should be replaced at  
least once per year.  
12.  
LOWER REAR ACCESS  
PANEL  
Allows access to Ansul® fire suppression agent tank (a6) and controls  
also access to main power contactor (41).  
a15.  
16.  
DISCHARGE NOZZLE  
GREASE BAFFLE  
Fire suppression media discharges here (2 places).  
Extracts and drains most grease and moisture from the air flow.  
18.  
PRE-FILTER ASSEMBLY  
Comprises the PRE-FILTER FRAME and a replaceable  
PRE-FILTER. Stops larger particles of grease from reaching the  
FILTER PACK for reduced maintenance costs.  
19.  
HI-EFFICIENCY/CHARCOAL  
FILTER PACK  
Stops most grease and smoke particles. Also assists in some cooking  
odor removal.  
22.  
28.  
GREASE DRIP TRAY  
Collects grease/moisture dripping from grease baffle(16).  
VENTILATOR EXHAUST  
DUCT  
Exit point for ventilator airflow - on top left rear of unit.  
DO NOT BLOCK  
a31.  
STATUS INDICATOR  
Displays status of fire suppression system (COCKED - FIRED) If  
FIRED, a buzzer will sound continuously.  
38.  
41.  
POWER CORD  
6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).  
POWER CONTACTOR  
Energizes cooking appliances only while ventilator section is sensed  
as operational.  
42.  
BUILDING FIRE ALARM  
RELAY  
Reports fire alarm condition to building fire management system.  
43.  
44.  
GROUND LUG  
Ground wire of power cord connects here.  
INTERLOCK TERMINAL  
Provides connection for shut-down control by building fire management  
system.  
53.  
FILTER INTERLOCK  
SWITCHES  
Proper installation of grease baffle and filter pack close these switches  
in ventilator sensor circuit.  
56.  
57.  
58.  
VENTILATOR FAN  
HOOD SIDE SHIELD  
SIDE SPACERS  
Provides air movement for ventilation.  
Required on left and right sides of hood. Factory installed.  
Required to maintain 6" spacing from combustibles. Field installed.  
3