TCB4 Upgrade Kit for LBB 3500/00, /10 and /30
LBB 3500/00 and LBB 3500/10
LBB 3500/30
SecuritySystems
Installation Instruction
en LBB 3519/20
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1. Upgrade Kit LBB 3519/20
en | 3
Chapter 1. Upgrade Kit LBB 3519/20
LBB 3500/xx
Introduction
TheupgradekitLBB3519/20isintendedforupgradingofthefollowingDCNCentral
Control Units:
TCB 2 or 3
•
•
•
LBB 3500/00 (D)
LBB 3500/10 (D)
LBB 3500/30 (D)
LBB 3500/xx (with upgrade)
The upgrade kit LBB 3519/20 (Trunk Communication Board (TCB 4)) once installed
in the Central Control Units provides the CCUs’ with a high speed serial RS 232
port. This port can be used for either ‘DIRECT’ connection to a DCN control PC,
camera control, test/diagnostic purposes or for remote control.
TCB 4
Single port only (Port 1)
The TCB4 has two Ports, Port 1 and Port 2. Both Ports can be used if a second hole is
made at the rear of the CCU housing to accommodate the second 9-pole D-type
connector.
NOTE: The default settings for Port 1 can be changed to suit
your requirements (see Chapter 3).
NOTE: If a second port is required, then an additional interconnection cable is
also required. This cable is ordered separately under Code No. 3922 156
24090, through your local Bosch supplier.
LBB 3500/xx (also applicable for LBB 3500/10)
TCB 2 or 3
REMARKS:
1. Using the ‘DIRECT’ connection method the PC-Network card LBB 3510/00 is
NO longer required.
2. If a ‘DIRECT’ connection is made between the Control PC and the CCU, the PC
LBB 3500/xx (with upgrade)
operator has no connection to the PC for headphone or intercom handset. Additional
DCN hardware is required for the operator if these functions are required. Use can be
made of DCN table-top or flush-mounted hardware depending on the requirements.
TCB 4
Two ports
Port 1 - ‘DIRECT’ connection to DCN control PC (default) (see Note)
Port 2 - Automatic camera control (default) (see Note )
NOTE: The default settings for Port 1 and 2 can be changed to
suit your requirements (see Chapter 3.).
FIGURE 1-1 CCU upgrade kit LBB 3519/20
Bosch Security Systems | April 03 | 3922 988 97112 en
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1. Upgrade Kit LBB 3519/20
en | 4
Installation procedure
1.1 Before you Begin
WARNING: Before performing any of the procedures described in this
1. Remove the top-cover from the CCU.
2. Locate the TCB (version 2 or 3). For location of the TCB see Fig 1-1.
document that require you to remove the top-cover of the CCU,
NOTE: For Multi-CCUs type LBB 3500/30 carefully remove the ‘Multi-CCU’
card from the TCB card. The TCB is located under the ‘Multi-CCU’ card.
3. Remove all interconnection cables from the TCB.
4. Remove the 6 screws securing the TCB,
1. Before removing the top cover of the CCU, disconnect the mains supply and
remove the mains cable from its source and from the rear of the CCU.
2. Disconnect any peripherals connected to the CCU
3. The TCB4 upgrade interface card is shipped in antistatic packaging for protection
from electrostatic damage.
5. Remove the TCB.
Once the TCB 2 or 3 is removed proceed as follows:
CAUTION: Before unwrapping the antistatic packaging, ground yourself by
touching any unpainted metal surface on the Central Control Unit. This proce-
dure discharges static electricity that might harm the interface card.
Minor modifications, (i.e. widening the holes to accommodate the 9-pole D-type
connector(s)) are required at the rear of the CCU. If the upgrade includes two Ports,
then an additional hole is required to accommodate Port 2.
REFERENCE: If available refer also to Chapter 4 of the latest
Digital Congress Network
Installation and Operating Manual
editionoftheDCNInstallationandOperatingManual.
(Code No. 3922 988 433xx).
1. Remove the TCB from its packaging (see 1.1 Before you Begin)
2. Position the TCB4 in place and secure using its 6 securing screws.
3. Position and secure the 9-pole D-type connector(s) in their modified hole(s).
4. With reference to FIGURE 1-1 and FIGURE 2-1 connect Port 1 and if applicable Port
2.
1.2 INSTALLING the TCB4 Interface card
5. Connect the TCB4 to both 1/O control boards.
6. Double check connections according to FIGURE 1-1 and FIGURE 2-1.
1. Your upgrade kit includes:
- 1 x TCB4 interface card
1.3 SET-UP of the TCB4 Interface card
- Interconnection (ribbon) cable terminated with a 9-pole D-type connector at one end
and a Micromatch connector at the other end.
To ensure correct operation of the TCB4, the following settings are required:
1. DIP-switch S14 must be set, to configure the communication protocol and baud
NOTE: If two ports are required, then an additional interconnection cable is also
required. This cable is ordered separately under Code no. 3922 156 24090,
through your local Bosch supplier.
rate used on Port 1 and Port 2 (see Chapter 3 ).
2. DIP-switch S9 must be set to configure the boards functionality (see Chapter 2.1 ).
3. Jumpers X13 and X14 must be set (see Chapter 2.2).
NOTE: Once the TCB4 has been successfully installed in the CCU, replace the
top-cover and connect the mains supply to the CCU. Check the CCU for cor-
rect operation. If the CCU functions correctly, the CCU should be switched ON
for at least 24 hours to charge the back-up battery located on the TCB4.
Bosch Security Systems | April 03 | 3922 988 97112 en
|